Organopolysilazane IOTA 9118 (Vinyl-Functional Liquid Polysilazane) for High-Temperature Easy-Clean Coatings: How to Choose the Curing Route and Apply?

Hits: 1373 img

Direct Answer

IOTA 9118 is a liquid polysilazane containing Si-N structures with vinyl groups as the main functional group, specially designed for high-temperature coating systems. Product data: light yellow transparent liquid, molecular weight 1200–1400, purity above 99% (other contents customizable), density 0.98–0.99 g/cm³, ceramic density 1.60–2.00 g/cm³, viscosity 10–40 cp, resin cracking threshold related to coatings of 100 µm and above, cured hardness 6–7H, coating water contact angle 100°–105°, recommended service temperature <800°C for clear coatings, <1600°C when used with a main coating, ceramic yield at 800°C of 50%–60%, ceramic conversion of the cured product at 800°C of 60%–70%, good chemical barrier properties for O2, H2O, and other gases, linear shrinkage <1%, visible-light transmittance >95%, metal adhesion by cross-cut grade 0, and shelf life one year unopened.

Curing data give two routes: (1) thermal curing, including baking above 250°C without initiator, baking above 250°C after adding a peroxide-type thermal crosslinker, and curing at 80–100°C with a platinum catalyst; (2) UV curing by adding a cleavage-type photoinitiator. The data also note: the resulting cured coating shows good service properties in indoor environments; the toughness of the cured coating decreases significantly after 400°C.

Selection should not rely only on “high-temperature resistant,” “6–7H,” or the contact-angle number. First confirm the substrate type—metal, alloy, glass, paint film, or plastics such as PP, PC, PVC, and PMMA—the application method (wiping, dip coating, spray coating, brush coating), target film thickness, curing route (thermal or UV, with or without initiator or platinum catalyst), whether ceramic conversion is required, whether it is a clear coating or used with a main coating, and the project acceptance criteria for adhesion, heat resistance, oxidation resistance, corrosion resistance, easy-clean performance, and non-flammability. This article does not equate these properties with a specific salt-spray duration, fire rating, or outdoor service life. IOTA can provide polysilazane raw materials and corresponding product data; the company does not provide complete formulations or formulation development services.

1. First Ask What IOTA 9118 Is Expected to Solve

IOTA 9118 is used in coatings, adhesives, non-combustible composites, polymer matrix composites, glass and abrasive fields, and easy-clean applications requiring low surface tension. Different applications focus on different points: high-temperature coatings on curing and heat resistance, easy-clean on surface tension and contact angle, adhesives on adhesion, composites on wetting and ceramic conversion, and glass and abrasives on transparency and application compatibility. Selection should start with the target defect and application, not just “high temperature resistant.”

2. What to Specify in an Inquiry or Sample Request

What to confirm What to specify in an inquiry or sample request
Substrate and pretreatment Metal, alloy, glass, paint film, PP, PC, PVC, PMMA, etc.; surface cleaning, sanding, primer, or other treatment
Coating role Clear coating or used with a main coating; whether used as primer, topcoat, or intermediate layer
Application method Wiping, dip coating, spray coating, brush coating; application viscosity, coating weight, target wet/dry film thickness
Curing route Thermal: above 250°C without initiator, above 250°C with peroxide-type thermal crosslinker, or 80–100°C with platinum catalyst; UV: with cleavage-type photoinitiator
Curing and ceramic conversion Curing temperature and time; whether ceramic conversion is required, target temperature, atmosphere, and heating schedule; UV curing requires light source, dose, and time confirmation
Film thickness and cracking Target film thickness; the data relate the resin cracking threshold to coatings of 100 µm and above; the actual thickness limit must be confirmed with the system
Acceptance criteria Adhesion, hardness, heat resistance, oxidation resistance, corrosion resistance, easy-clean performance, contact angle, non-flammability, transparency, etc.
Sample preparation Sample size, substrate batch, number of coating passes, whether a main coating is used, whether service above 400°C is involved, sample quantity

If the customer already has a test specification, obtain the original document first. When criteria are missing, confirm them with the project owner and test laboratory before making samples, so that both sides do not discover different interpretations of “pass” after testing.

3. Choose the Curing Route Before Discussing Coating Performance

IOTA 9118 has two curing route categories: thermal curing and UV curing. Thermal curing has three methods:

  1. Without initiator: baking above 250°C;

  2. With peroxide-type thermal crosslinker: baking above 250°C;

  3. With platinum catalyst: curing at 80–100°C.

UV curing requires adding a cleavage-type photoinitiator. The data do not give UV wavelength, dose, or specific time; obtain these from the supplier or confirm with the actual light source and film thickness. Do not assume them.

Different curing routes correspond to different equipment conditions, substrate heat tolerance, and process windows: baking above 250°C requires the substrate and main coating to withstand that temperature; the platinum-catalyst 80–100°C route suits substrates with lower heat tolerance; UV curing suits cases requiring rapid setting or where high temperature is unsuitable. Confirm substrate heat tolerance and equipment capability first, then choose the route; do not mix curing conditions from different routes.

4. Coating Role Determines the Temperature Boundary

The product data separately state: recommended service temperature <800°C for clear coatings; <1600°C when used with a main coating. These two temperature boundaries cannot be mixed. When used alone as a clear coating, understand it as <800°C. Only when used together with a main coating should the <1600°C recommended range be discussed, and even then it must be confirmed with the main coating system, substrate, and actual service conditions.

The data also note: the resulting cured coating shows good service properties in indoor environments; the toughness of the cured coating decreases significantly after 400°C. Therefore, if the application involves temperatures above 400°C, toughness and cracking resistance should be specifically evaluated; hardness or adhesion data alone cannot be used to infer mechanical state after high temperature.

5. Evaluate Substrate Compatibility and Adhesion Separately

The product data state good adhesion to metals, ceramics, and other materials, with metal adhesion by cross-cut grade 0, and applicability to metals, alloys, glass, paint films, and plastics such as PP, PC, PVC, and PMMA. Different substrates have different surface energies, polarity, and heat tolerance; grade 0 adhesion on metal cannot be directly used to infer all plastics and paint films. Plastic substrates especially require separate confirmation of adhesion, curing-temperature compatibility, and deformation risk. If thermal curing above 250°C is used, first confirm whether the plastic substrate can withstand that temperature.

Application methods include wiping, dip coating, spray coating, and brush coating. Different methods have different requirements for viscosity, film thickness, and spreading, and should be confirmed with representative samples.

6. Understand Property Data, Ceramic Yield, and “Non-Flammability” Under Specific Conditions

Cured hardness 6–7H, coating water contact angle 100°–105°, metal adhesion by cross-cut grade 0, visible-light transmittance >95%, linear shrinkage <1%, and good chemical barrier properties are typical data under the corresponding conditions in the product data. Hardness, contact angle, and adhesion are affected by substrate, film thickness, curing route, and ceramic conversion; transparency should also be confirmed separately on the target film thickness and substrate.

Ceramic yield at 800°C of 50%–60% and ceramic conversion of the cured product at 800°C of 60%–70% are data at 800°C and cannot be directly extrapolated to other temperatures or arbitrary atmospheres. “Non-flammable after curing” is a material characteristic description, not the same as having passed a specific fire standard or fire rating. Fire rating, smoke toxicity, and durability requirements for non-combustible composite projects must be verified separately according to the project specification. For corrosion resistance or oxidation resistance, the “corrosion resistance” and “oxidation resistance” features should be translated into specific media, temperature, time, and evaluation methods.

7. Film Thickness and Cracking Risk Require Particular Attention

The data relate the resin cracking threshold to coatings of 100 µm and above, indicating that cracking risk requires particular attention as film thickness increases. Simply increasing thickness is not a universal solution. If used above 400°C, toughness reduction and cracking risk should be evaluated together. When comparing candidate solutions, keep substrate, pretreatment, and curing route as consistent as possible; if film thickness, initiator, or additional layers are changed, record them separately.

8. Prepare Samples in This Order Before Sending

  1. Obtain the customer’s service conditions and acceptance criteria; confirm whether heat resistance, adhesion, oxidation resistance, corrosion resistance, easy-clean performance, and non-flammability are targets or existing results.

  2. Specify substrate, surface treatment, coating role (clear coating or used with a main coating), application method, target film thickness, curing route (thermal or UV), initiator or catalyst type, and ceramic conversion schedule.

  3. Check the current IOTA 9118 data, then have the user make representative samples and keep records of formulation, dilution, application, curing, and heating profile; for UV curing, also record light source, dose, and time.

  4. Arrange tests as agreed; keep sample identity, test conditions, observation photos, and evaluation results in the report. Before expanding use, confirm whether the samples represent actual workpieces.

IOTA/Anhui Iota Silicone Oil Co., Ltd. positions itself as a solution provider across the organosilicon industry chain and can provide polysilazane raw materials and corresponding product data. When communicating, provide the substrate, existing coating system, application equipment, curing conditions, target defects, and whether service above 400°C is involved together to facilitate candidate screening; the company does not provide complete formulations or formulation development services.

FAQ

1. Can you directly recommend an IOTA 9118 clear-coat formulation for 1600°C?

That cannot be directly assumed. The data state recommended service temperature <800°C for clear coatings and <1600°C when used with a main coating. The coating role, main coating system, and actual service conditions must be defined before evaluation.

2. How to choose between thermal curing and UV curing?

Thermal curing has three methods: above 250°C without initiator, above 250°C with peroxide-type thermal crosslinker, and 80–100°C with platinum catalyst. UV curing requires a cleavage-type photoinitiator. The choice should be confirmed with substrate heat tolerance, equipment, film thickness, and process pace.

3. What is the difference between no initiator and peroxide-type thermal crosslinker?

The data state both require baking above 250°C. Whether to add a peroxide-type thermal crosslinker should be confirmed with the formulation and curing window; the conditions of the two should not be mixed.

4. Is platinum-catalyst curing at 80–100°C suitable for all substrates?

No. This route suits substrates with lower heat tolerance, but adhesion, cure degree, and subsequent service temperature still need confirmation; it cannot be directly inferred to suit all substrates.

5. What conditions are needed for UV curing?

The data only say “add a cleavage-type photoinitiator” and do not give wavelength, dose, or time. Obtain specific conditions from the supplier and confirm with the actual light source and film thickness.

6. Toughness decreases significantly after 400°C—how does this affect selection?

The data explicitly note that the toughness of the cured coating decreases significantly after 400°C. If the application involves temperatures above 400°C, toughness and cracking resistance should be specifically evaluated; hardness or adhesion alone cannot be used to infer mechanical state after high temperature.

7. Does a contact angle of 100°–105° mean corrosion resistance has passed?

No. Contact angle reflects surface wetting characteristics. Corrosion resistance also depends on film integrity, adhesion, media, and post-test corrosion.

8. Does non-flammable after curing mean passing a specific fire rating?

No. Non-flammability is a material characteristic description. Specific fire rating, smoke toxicity, and durability requirements must be verified separately according to the project specification.

Online QQ Service, Click here

QQ Service

What's App